Aerial telecommunication cable
Air telecommunication cables are in better condition in terms of flexibility and are used in the indoor environment of the building.
Technical Specifications:
Telecommunication cable according to IEC 60189, 0815 VDE, TCI standards
Temperature requirements and allowed heat:
-5oC to +50oC in flex mode
In fixed installation mode -30oC to 70oC
Rated voltage: 200V max
Insulation resistance:
At least 500m km*ohm
Mutual capacitor:
1000HZ Km/nF at 0.1, 0.5, 0.6, and 0.8 mm
Structure:
Hadi:
Tin-plated or tin-free annealed copper with a conductor diameter of 0.6
Insulation:
Polyethylene HD 52518 or LD020. Strings are paired with suitable warp length and different from each other
Electrostatic protection:
Polyester tape + ground wire + PVC coated aluminum foil and is generally gray in color.
Application:
In telephone facilities inside buildings and telephone centers, it is permanently installed under or on the wall. Outside the building, it is only allowed to be installed on the wall, and it is not allowed to use it underground.